Honeywell NS1 Access Control Application PDF Installation Guide
Thank you for using NS1 for your access control application. NS1 is a powerful access control system which can be used for single door access, as well as for connection to any type of on-line access control system. NS1 units can also be mounted in an RS485 network without the necessity of an external access control system. NS1 as a single door unit offers many possibilities such as:
• Access control
• Unlock option
• Day/Nightlock option (manual or automatic switching)
• Long range reader (up to 45cm)
• Optional use of PIN keypad
• Using an external relay (to prevent potential tampering)
• NS1 Manage software for stand-alone PC programming, event logging and user database maintenance
The NS1 Proximity Reader has two operating levels:
• Installer Level. On this level the NS1 can be configured by the Installer. This level is also used to do typical Installer options.
• User Level. On this level typical user options can be set, such as adding and voiding user cards, setting the door open time, etc. This Quick Guide explains the most frequently used Installer settings that can be used to configure the NS1. Please refer to the NS1 User Guide (TD1168) for user related settings. The programming steps mentioned in this Quick Guide represent a limited number of programming functions that can be performed by the Installer on an NS1. Please refer to the NS1 Master Manual (TD0099) for all the possibilities.
In this Quick Guide, configuring the NS1 Proximity Reader is described by means of a Remote Programmer. However, there are other ways. Northern also offers the possibility of programming the NS1 Proximity Reader through the NS1 Manage PC software. If you have to install this application, please refer to the installation instructions of the NS1 Manage manual (TD0099).
The following steps describe how to configure the NS1.
1. Wake up the NS1 from sleep mode. When powering up the NS1 for the first time, the NS1 is in the Installer sleep mode. This programmer will automatically become the Installer Remote Programmer. It is recommended to identify the Remote Programmer as the Installer by labelling it such.
2. Set the Lock Type (23*). Different lock types can be set by entering the key sequence corresponding with the lock type. See the following table for information.
3. Set Open Time-out (11*). Whenever access is granted, the relay of the NS1 will be activated during a certain number of seconds, called the Open Time-Out. This period of time can be adjusted from 1 to 255 seconds. The default value is 2 sec, meaning that after presenting the tag to the NS1 reader, you have 2 seconds to open the door. If you want to use the default value, skip this step and proceed with the next. To use a setting other than the default one, perform the steps indicated in Figure 5.
Download Honeywell NS1 Access Control Application PDF Installation Guide